Cookie Img

Greystone Low Pressure Transmitter LP3 Series

Greystone Low Pressure Transmitter LP3 Series
Greystone Low Pressure Transmitter LP3 Series
Product Code : LP3 Series
Product Description

Greystone Low Pressure Transmitter LP3 Series

FEATURES:

  • Jumper selectable 2 wire current and 3 wire voltage outputs
  • 24 Vac/dc power supply
  • Six variable jumper selectable pressure ranges, W.C. & Pa.
  • Available options include LCD display and integrated static probe
Specification

Accuracy:

±1% F.S.O.

Measurement Type:

Differential (two port)

Response Time:

250 ms

Stability:

< ±1% F.S.O. per year

Thermal Effects:

< ±3% over compensated range

Compensated Range:

0 - 50° C (32 - 122°F)

Proof Pressure:

40” W.C. (100“ for 12” and 20“ models)

Burst Pressure:

60” W.C. (200” for 12” and 20” models)

Operating Conditions:

0 - 70°C (32 - 158°F), 10 - 90 %RH, non-condensing

Media Compatibility:

Non-corrosive, non-ionic fluids such as clean dry air or inert gases

Power Supply:

20 - 28 Vac/dc (non-isolated half-wave rectified)

Supply Current:

< 4 mA

Input Voltage Effect:

Negligible over specified operating range

Protection Circuitry:

Reverse voltage protected and out limited

Output Signal:

4-20 mA (2-wire), 0-5 or 0-10 Vdc (3-wire), switch selectable


Greystone Low Pressure Transmitter LP3 Series

FEATURES:

  • Jumper selectable 2 wire current and 3 wire voltage outputs
  • 24 Vac/dc power supply
  • Six variable jumper selectable pressure ranges, W.C. & Pa.
  • Available options include LCD display and integrated static probe
Specification

Accuracy:

±1% F.S.O.

Measurement Type:

Differential (two port)

Response Time:

250 ms

Stability:

< ±1% F.S.O. per year

Thermal Effects:

< ±3% over compensated range

Compensated Range:

0 - 50° C (32 - 122°F)

Proof Pressure:

40” W.C. (100“ for 12” and 20“ models)

Burst Pressure:

60” W.C. (200” for 12” and 20” models)

Operating Conditions:

0 - 70°C (32 - 158°F), 10 - 90 %RH, non-condensing

Media Compatibility:

Non-corrosive, non-ionic fluids such as clean dry air or inert gases

Power Supply:

20 - 28 Vac/dc (non-isolated half-wave rectified)

Supply Current:

< 4 mA

Input Voltage Effect:

Negligible over specified operating range

Protection Circuitry:

Reverse voltage protected and out limited

Output Signal:

4-20 mA (2-wire), 0-5 or 0-10 Vdc (3-wire), switch selectable


Contact Us

No. 124, Sunrise Mall, Near Swaminarayan Mandir, Judges Bungalow Road, Vastrapur, Ahmedabad, Gujarat, 380015, India
Phone :91-79-40027338